| Valve Specifications | |
| Valve Material | Fiber reinforced polymer |
| Inlet/Outlet | 3/4" or 1" |
| Cycles | 5 |
| Flow Rates (50psi Inlet) - Valve Alone*† | |
| Continuous (15psi drop) | 19GPM |
| Peak (25psi drop) | 24GPM |
| CV (1psi drop) | 4.8GPM |
| Max. Backwash (25psi drop) | 17GPM |
| Regeneration | |
| Downflow/Upflow | Downflow Only |
| Adjustable Cycles | Yes |
| Time Available | Electromechanical: 164 minutes SXT: 199 minutes per cycle |
| Meter Information | |
| Meter Accuracy Range | 0.25 - 15gpm +/- 5% |
| Meter Capacity (Gal.) |
Standard: 125 - 2,125 Extended: 625 - 10,625 SXT: 1 - 999,900 |
| Dimensions | |
| Distributor Pilot | 1.05" O.D. |
| Drain Line | 1/2" O.D. |
| Brine Line | 3/8" |
| Mounting Base | 2-1/2" - 8 NPSM |
| Height From Top of Tank | 7-1/2" |
| Typical Applications | |
| Water Softener | 6" - 16" diameter (limited by max injector size) |
| Filter System | 8" - 16" diameter (based on 10GPM per ft2 |
| Additional Information | |
| Injector Brine System | 1600 |
| Electrical Rating‡ | 24v, 110v, 220v - 50Hz, 60Hz |
| Max VA | 72 |
| Estimated Shipping Weight |
Time clock - 7lbs. Metered - 10lbs. |
| Pressure |
Hydrostatic: 300psi Working: 20 - 125psi |
| Temperature | 34° - 110° |
| *Maximum flow rate shown is the maximum the valve is capable of, maximum service flow rates will vary depending on system type & size †Flow rates are for standard pistons, air injection system flow rates may vary ‡Standard setup is 110v - 60Hz, other setups may be available at an additional charge |
|

Fully adjustable 5-cycle top mount control delivers controlled upflow backwash, downflow brining and slow rinse, rapid rinse, brine refill and downflow service
Time-tested hydraulically balanced piston, seal and spacer concept to control service flow and regeneration
Non-corrosive, high-tech material construction
Excellent flow rates – 19 GPM continuous, 24 GPM peak
Backwash capacity handles tanks up to 16˝ diameter for softener applications, 16˝ diameter for filter applications
Mechanical or Electronic control, meter initiated or 12-day time clock regeneration available
Corrosion-free bypass valve
Backwash filter
Meter initiated regeneration
Manual operation
Environmental cover
No hard water bypass piston
Auxiliary switches